double balanced mi x er rf band model M73T rf 0.8 to 2.4 ghz rf (ghz) 0.8-2.4 0.8-2.4 0.8-2.4 0.8-2.4 lo (ghz) 0.8-3.5 0.8-2.0 2.0-3.5 0.8-3.5 0.8-3.5 0.8-3.5 0.8-3.5 0.8-3.5 if (ghz) d c -1.5 d c -1.5 d c -1.5 d c -1.5 min 25 db 20 db 18 db max 10.5 db condition s electrical specifications (1) : parameter ssb conversion loss: (2) isolation l o to rf: lo to if: input 1 db compression point: desensitization point: (rf2 @ -1 dbm) input third order intercept point: lo power: (3) notes: 1. specifications are guaranteed when tested as a downconverter in a 50 ohm system at +25 ? c with +7dbm lo powe r . specifications indicated as typical are not guaranteed. 2. ssb noise figure is nominally within 0.5 db of the ssb conversion loss for if frequencies greater than 10 mhz. 3. usable lo drives are up to 2 db below and 3 db above nominal. all dimensions are in inches and [mm]. t ypical p er f o r mance a t 25? c outline: a M73T typical 9.0 db 36 db 30 db 21 db +0 dbm +1.0 dbm +10 dbm +7 dbm spectrum microwave 2144 franklin drive n.e. palm ba y , fl 32905 ph (888) 553-7531 fax (888) 553-753 2 spectrum microwave 2707 black lake place philadelphia, pa 19154 ph (215) 464-4000 fax (215) 464-4001 ww w .spectrummicrowave.co m specifications rev. 2/26/09
|